- Manuals
- Brands
- t.a.c. Manuals
- Control Panel
- Xenta OP
- Handbook
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
0-004-7506-4 (EN), 2001-08-08
TAC Xenta
Handbook
AH02: West
_STATUS
TEMPERATURES
ALARMS
® ® ® ® ®
OP
Summary of Contents for t.a.c. Xenta OP
-
Page 1
AH02: West _STATUS TEMPERATURES ALARMS ® ® ® ® ® TAC Xenta Handbook 0-004-7506-4 (EN), 2001-08-08… -
Page 3
TAC representative. You may also want to send an e-mail to helpdesk@tac.se. This edition, -4, applies to TAC Xenta OP version VMX 3.2 or later. The procedure for de-installation of the OP has been clarified and put in a separate section, 2.7. -
Page 4
TAC Xenta OP Handbook Foreword Copyright © 2001 TAC AB. This document, as well as the product it refers to, is only intended for licensed users of the product and the document. TAC AB owns the copyright of this document and reserves the right to make changes, additions or deletions. -
Page 5: Table Of Contents
Contents TAC Xenta OP Handbook Subject to modification. Contents Introduction ……………………7 TAC Xenta OP ……………………….7 This manual ……………………….7 More information ……………………..8 Connection and Basic Functions ………………. 9 Description ……………………….. 9 Connecting to TAC Xenta 100 ………………….10 Connecting to TAC Xenta 300/401 ………………..
-
Page 6
TAC Xenta OP Handbook Contents Technical data ………………….. 31 Index ……………………….33 This manual contains a total of 36 pages. 6 (36), 0-004-7506-4 (EN) TAC AB, 2001-08-08… -
Page 7: Introduction
1 Introduction Introduction 1.1 TAC Xenta OP TAC Xenta OP is a small operator panel designed to be used together with TAC Xenta 100, 300, 401 and 901 units. The operator panel gives the user access to parameters and alarms without communicating with a central system.
-
Page 8: More Information
• the “TAC Menta User’s manual” Stand-alone TAC Xenta 300/3000 controllers and I/O modules can be commissioned by using the Service menu of TAC Xenta OP (which is not the same as the local OP service menu). This procedure is de- scribed in the TAC Xenta 300 and 401 Handbook.
-
Page 9: Connection And Basic Functions
2 Connection and Basic Functions Connection and Basic Functions 2.1 Description The TAC Xenta OP Operator panel has an LCD display with 4*20 characters and six push buttons. A modular socket or four screw terminals are used for communication and for connecting the power supply.
-
Page 10: Connecting To Tac Xenta 100
2.2 Connecting to TAC Xenta 100 Normally the TAC Xenta OP is connected to the modular jack on the lower side of the Wall Module. In this way the Xenta OP will get power supply from the TAC Xenta 100 unit.
-
Page 11: Connecting To Tac Xenta 300/401
Service pin Modular socket on the OP TAC Xenta OP connectors and contrast potentiometer The contrast of the display can be adjusted with the potentiometer on the rear of the operator panel. (The Service pin is available from the rear if, in special cases, the network configuration procedure requires this.
-
Page 12: Keys
TAC Xenta OP Handbook 2 Connection and Basic Functions 2.4 Keys The TAC Xenta OP keys: – is used to step up one level in the directory hierarchy (“Home”). There may be several levels in the hierarchy. The cursor will return to the line selected the last time this level was active.
-
Page 13: Local Functions Of The Op Service Menu
TAC Xenta OP Handbook 2 Connection and Basic Functions 2.5 Local functions of the OP Service menu For simple hardware check of the OP and for certain system param- eters there is a local Service menu in the operator panel. The OP…
-
Page 14
TAC Xenta OP Handbook 2 Connection and Basic Functions Selecting the language of the OP messages means that the operator can switch between different languages for 5. National text those messages that are generated in the OP. Select language No reply … -
Page 15: Selecting The Op Communication Mode
TAC Xenta OP Handbook 2 Connection and Basic Functions 2.6 Selecting the OP communication mode Xenta 100: ON/OFF When delivered, the OP is set for Base unit (TAC Xenta 300, 400) communication. To change the communication mode, you have to call up the OP Service menu and go to the 10.OP mode menu, where the…
-
Page 16
TAC Xenta OP Handbook 2 Connection and Basic Functions To turn OFF the Xenta 100 mode Press enter to 1 (Disconnect and then) connect the OP; wait for a couple of access Xenta 100 seconds for the Base unit message to appear. -
Page 17: De-Installing The Op
TAC Xenta OP Handbook 2 Connection and Basic Functions 2.7 De-installing the OP If the OP is to be de-installed from the network, it should be restored to the original factory setting to avoid problems, if used in another network.
-
Page 18: Tool: Lonmaker
TAC Xenta OP Handbook 2 Connection and Basic Functions 2.7.2 Tool: LonMaker 1 Check in the OP Service menu – 10. OP mode that Bindable is set to “TAC” or, in OP version < 3.11 to “OFF”. 2 Start the LonMaker Browser.
-
Page 19: Dialogs With Tac Xenta 100
3.2 Connecting to TAC Xenta 100 Note! The very first time a TAC Xenta OP is connected to a Xenta network, the TAC Xenta 100 communication mode is, by default, in the Off state. Please refer to the end of chapter 2 for the necessary procedures to change the communication mode.
-
Page 20
TAC Xenta OP Handbook 3 Dialogs with TAC Xenta 100 Wait for the display Xenta 100 is: Configured Press <DOWN> to continue Press the key and wait for a display looking like: Xenta 103v1.00-10 103/A/v10003 units as SI [^] NV index? 000 The first two lines, showing software versions, are displayed the first time only. -
Page 21: Setting The Node State In Tac Xenta 100
Configured Configured/Unconfigured are normally set by a binding tool, in a network configuration and by TAC Xenta OP in a stand-alone configuration. See also the TAC Xenta Network guide. 3.4 Reading/checking NVs in TAC Xenta 100 When connection has been established (section 3.2) a NV (Network Variable) index can be selected by the use of the –…
-
Page 22: Initiate Service Pin Message
TAC Xenta OP Handbook 3 Dialogs with TAC Xenta 100 Input variables appear further down in the list: Example: Select NV 013 to get the Application Mode: 13 nviApplicMode Auto nvi indicates that this is an input value. The cursor is visible and allows the value to be changed from the OP.
-
Page 23: Dialogs With Tac Xenta 300 And 401
Cyrillic characters The TAC Xenta OP/RU model has the capability of displaying Cyrillic characters. The TAC Menta User’s manual describes how you switch the charac- ter files of the OP.
-
Page 24: Find And Change A Setpoint
TAC Xenta OP Handbook 4 Dialogs with TAC Xenta 300 and 401 4.2 Find and change a setpoint This example starts with the first screen showing all TAC Xenta 300/ 401 controllers in the network and shows how to find and change the supply air setpoint in “AH02 West”:…
-
Page 25: View/Acknowledge Alarms
TAC Xenta OP Handbook 4 Dialogs with TAC Xenta 300 and 401 4.3 View/acknowledge alarms To make the operator aware of unacknowledged alarms in the alarm list the abbreviated application/base unit name (“AH02” in our exam- ples) will flash. When the item “Alarms” has been found and selected…
-
Page 26: Change The Time Channels
TAC Xenta OP Handbook 4 Dialogs with TAC Xenta 300 and 401 If a TAC Xenta controller is connected to a supervisory system like TAC Vista, another indication may appear in the alarm list. An asterisk (*) in front of the signal name means that the alarm is blocked, that is, information about changes between alarm on and alarm off will not be sent to TAC Vista.
-
Page 27
TAC Xenta OP Handbook 4 Dialogs with TAC Xenta 300 and 401 To get to the next schedule controlling AH02 press once. AH02: Time schedule 1234567 08:00–12:00 As the cursor is positioned under “08”, must be pressed twice to move the cursor to “12”. Use to change the off hour to –… -
Page 28: Access Code
TAC Xenta OP Handbook 4 Dialogs with TAC Xenta 300 and 401 Special cases If you want the time channel to be turned off for the whole day and night and use the 24 hour clock, you indicate this by 00:00-00:00 and with the AM/PM clock (please refer to section 4.1)
-
Page 29: Edit Access Code
TAC Xenta OP Handbook 4 Dialogs with TAC Xenta 300 and 401 4.6 Edit access code To change the code that gives the operator access to the medium or high level items, the access level code for the level to be changed must first be entered as described above.
-
Page 30: Daylight Saving
TAC Xenta OP Handbook 4 Dialogs with TAC Xenta 300 and 401 4.8 Daylight saving TAC Xenta 300 has built-in support for the European standard day- light saving. However, the OP can be used to set other conditions. To change the Daylight saving period, the following menu is used.
-
Page 31: Technical Data
TAC Xenta 901 ……modular jack or screw terminal Standards: Emission…………… EN 50081-1 Immunity …………..EN 50082-1 Part number: Operator terminal TAC Xenta OP …….. 0-073-0907 Operator terminal TAC Xenta OP/RU ……0-073-0923 Mounting kit panel TAC Xenta OP ……0-073-0904 TAC AB, 2001-08-08 0-004-7506-4 (EN), 31 (36)
-
Page 32
TAC Xenta OP Handbook 5 Technical data Blank page. 32 (36), 0-004-7506-4 (EN) TAC AB, 2001-08-08… -
Page 33: Index
TAC Xenta OP Handbook Index Index Special characters override 29 override indicator (->) 29 * 26 hhAmm 23 ** 27 hhPmm 23 -> 29 Holiday chart 27 push buttons 12 24 hour clock 23, 28 Inch-Pound 20 returned 25 access code 28…
-
Page 34
TAC Xenta OP Handbook Index Blank page. 34 (36), 0-004-7506-4 (EN) TAC AB, 2001-08-08… -
Page 36
Head office Finland UK, Ireland Poland Singapore For more information, come Sweden (358) 9 584 25 00 (44) 1582 81 67 00 (48) 58 782 00 11 (65) 748 23 93 and visit us on the Web at: (46) 40 38 68 50 China Office Germany, Austria, Norway…
Панель оператора модификации TAC Xenta ОР производства французского концерна Schneider Electric предназначается для возможности осуществления управления показателями. Кроме того, подобное приспособление используется для получения информационных сведений о сигналах непосредственно при применении с любыми моделями свободно программируемых контроллеров линейки TAC Xenta Шнайдер Электрик.
TAC Xenta OP представляет собой кнопочную панель небольших габаритных размеров. Используя данное приспособление, оператор может осуществлять управление такими моделями программируемых логических контроллеров из коллекции TAC Xenta, как ПЛК 100, 280, 300, 401 и 901. Управленческая панель данного вида оборудована жидкокристаллическим монитором, который состоит из четырех строк по двадцать символов в каждой. Также на операторской панели имеется шесть кнопок для выполнения управления контроллерами.
При необходимости устройство можно с легкостью зафиксировать на самом программируемом контроллере, например, на передней внешней дверце щитка. Как вариант, панелью оператор может пользоваться как переносным приспособлением и осуществлять управление на определенной дистанции.
При помощи эксплуатации такого прибора можно с удобством осуществлять регулирование контроллеров линейки TAC Xenta. Вводить необходимые данные можно, используя шесть функциональных клавиш, при этом информация будет выводиться на жидкокристаллический экран с подсветкой. Это весьма удобно. Поэтому всем, у кого есть потребность эффективно управлять программируемыми ПЛК в системах промышленной автоматизации, рекомендуется операторскую панель Tac Xenta купить и применять на практике. Подобный инструмент существенно упростит работу с системой.
Где можно приобрести операторские панели Tac Xenta op по выгодной цене?
Фирменную продукцию компании Schneider Electric, в частности операторские панели Tac Xenta op, купить любой потребитель может, сделав заказ на сайте фирмы fgrus.ru, которая многие годы является одним из лучших импортеров высококачественных продуктов зарубежных и отечественных брендов. Компания гарантирует доставку товаров в целости и сохранности в самые кратчайшие сроки в любой населенный пункт РФ, включая страны СНГ.
К тому же, в интернет-магазине fgrus.ru предлагаются справедливые цены на все панели операторов Шнайдер Электрик и другие позиции из электронного каталога.
TAC Xenta представляет собой линейку программно-логических контроллеров производства французского концерна Schneider Electric. Подобное оборудование применяется для обеспечения возможности управлять отопительными, вентиляционными системами, а также системами климат-контроля. Приспособления весьма функциональны. Они обладают контурами регулирования, температурными графиками, могут осуществлять управление относительно времени, обрабатывать аварийные ситуации и тому подобное.
Контроллеры Tac Xenta принадлежат к свободно программируемым ПЛК с дополнительными функциями коммуникации. Приспособления также созданы специально для работы в отопительных, вентиляционных системах, а также для улучшения эффективности кондиционирования. В устройстве отсутствуют свои входные и выходные слоты, однако к нему можно подключить не более десяти дополнительных расширительных блоков.
Панель оператора модификации TAC XENTA OP, производимой французским концерном Schneider Electric, предназначена для возможности управления индикаторами. Кроме того, такое устройство используется для получения информации о сигналах напрямую при использовании с любыми моделями свободно программируемых контроллеров линейки TAC Xenta компании Schneider Electric.
Панель операторов TAC Xenta OP, по сути, представляет собой специализированную клавиатуру небольшого размера. С помощью подобного модуля оператор может управлять такими моделями программируемых логических контроллеров из коллекции TAC Xenta, как ПЛК 100, 280, 300, 401 и 901. Панель управления этого типа оснащена ЖК-монитором, который состоит из четырех строки по двадцать символов в каждой. На панели оператора также есть шесть кнопок для управления контроллерами.
При необходимости устройство можно легко прикрепить к программно-логическому контроллеру, например, на передней внешней дверце приборной панели. В качестве альтернативы оператор может использовать панель как портативное устройство и управлять им на расстоянии.
Благодаря использованию такого устройства можно удобно настраивать контроллеры серии TAC Xenta. Вы можете ввести необходимые данные с помощью шести функциональных клавиш, а информация будет отображаться на ЖК-экране с подсветкой. Довольно удобно. Поэтому всем, кому необходимо эффективно управлять программируемыми контроллерами ПЛК в системах промышленной автоматизации, мы рекомендуем TAC XENTA OP купить.
Где купить операционные панели Tac Xenta по выгодной цене?
Панель TAC XENTA купить, как и другое фирменное вспомогательное оборудование Schneider Electric, может любой потребитель, разместив заказ на сайте АКС, который на протяжении многих лет является одним из лучших импортеров качественной продукции зарубежного и отечественного производства бренда. Компания гарантирует доставку товара в целости и сохранности в кратчайшие сроки в любой населенный пункт Российской Федерации, включая страны СНГ.
Кроме того, интернет-магазин АКС предлагает справедливые цены на все панели оператора Schneider Electric и другие товары из электронного каталога.
Не нашли, что искали?
Отправьте заявку: запросим наличие и цены у партнеров или дилеров
Detail Specifications: 1318/1318560-tac_xenta_op.pdf file (26 Mar 2023) |
Accompanying Data:
TAC Vista TAC Xenta OP Controller PDF Manual (Updated: Sunday 26th of March 2023 10:30:58 AM)
Rating: 4.1 (rated by 50 users)
Compatible devices: iCPE, ID5101, digitax st series, Sageon PSMC I, ROIbot BA-II Series, Bock LR, KTS DN 32, GPIB-232CT-A.
Recommended Documentation:
Text Version of Manual
(Ocr-Read Summary of Contents, UPD: 26 March 2023)
-
1, TAC Vista TAC Xenta OP TAC Vista 03-00058-01-en TAC Xenta OP is a small operator panel designed to be used with the TAC Xenta 100, 300 or 400 units. It has an LCD display with 4×20 characters and six push buttons. TAC Xenta OP/RU can also display Cyrillic characters. TAC Xenta OP is connected via a modular jack situated on the rear of the unit. Both communication and power supply are handled by this cable…
-
2, Copyright © 2007, TAC All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. All rights reserved. 03-00058-01-en Europe / Headquarters Malmö, Sweden +46 40 38 68 50 Americas Dallas, TX +1 972-323-1111 Asia-Pacifi c Sydney, Australia +61 2 9700 1555 www.tac.com Figur…
Recommended Instructions:
HR-SC, H-1604, 420, CKA 580, MPK 49
-
Please file in Service Binder5693 985 — 02 09/2016VITOTRONIC r 200-HVitotronic 200-HType HK1B Weather-compensated, digital heating circuit control unitsProduct may not be exactly as shownRead and save these instructionsfor future reference.IMPORTANTCertified as a component part for Viessmann boilersInstallation and Service Instructionsfor use by heating contractor …
vitotronic 200-h 80
-
Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-STOCK ITEMS• EQUIPMENT DEMOS• HUNDREDS OF MANUFACTURERS SUPPORTED• LEASING/MONTHLY RENTALS• ITAR CERTIFIED SECURE ASSET SOLUTIONSSERVICE CENTER REPAIRSExperienced engineers and technicians on staff at our …
I/O Plexer 64
-
Smart energy wifi wireless controller an instruction manualCopyright © SmartEnergy Electronic Technology. All rights reserved.ISMART ENERGY WIFI WIRELESSCONTROLLER AN INSTRUCTIONMANUALREV 1.0Smart Energy Electric Technology(Changzhou)Co.,LtdAdd: Changzhou City Wujin District Tianan Cyber Park Block C 301Tel: +86 519 8525 6609Fax +86 519 8525 6607http://www.smartenergy …
SMT-CMN-WIFI 10
Additional Information:
Product Types by TAC Vista:
- Controller
Popular Right Now:
Operating Impressions, Questions and Answers:
Свободно программируемые контроллеры Schneider Electric TAC Xenta
Семейство TAC Xenta 280/300/400 состоит из различных устройств:
- • Контроллер TAC Xenta 280/300/401. Контроллер – основной элемент системы. Он имеет системное и прикладное программное обеспечение для всех функций, которые должны выполняться контроллером.
- • TAC Xenta OP — панель оператора с дисплеем. Значения представлены в виде меню. TAC Xenta OP может быть связана с любым контроллером в сети.
- • Модули расширения входа — выхода служат для увеличения числа входов и выходов на контроллере TAC Xenta 300/401
Свободно программируемые контроллеры |
|||||||||
_______Модель________ |
___Сеть___ |
__Dl__ |
__Tl__ |
__Ul__ |
__DO__ |
__AO__ |
Сертификат_Lon_Mark |
Модули_расширения |
_______________Дополнительно_______________ |
TAC Xenta 701 |
TP/FT-10 |
0 |
0 |
0 |
0 |
0 |
10 модулей |
TCP/IP, Web-сервер для установки и обслуживания |
|
TAC Xenta711 |
TP/FT-10 |
0 |
0 |
0 |
0 |
0 |
10 модулей |
TCP/IP, полнофункциональный web-сервер |
|
TAC Xenta 721 |
TP/FT-10 |
0 |
0 |
0 |
0 |
0 |
20 модулей |
TCP/IP, Web-сервер для установки и обслуживания |
|
TAC Xenta 731 |
TP/FT-10 |
0 |
0 |
0 |
0 |
0 |
20 модулей |
TCP/IP, полнофункциональный web-сервер, поддержка Modbus, MicroNet и интерфейс EAC |
|
TAC Xenta 281 |
TP/FT-10 |
2 |
0 |
4 |
3 |
3 |
да |
||
TAC Xenta 282 |
TP/FT-10 |
2 |
2 |
4 |
4 |
4 |
да |
||
TAC Xenta 283 |
TP/FT-10 |
2 |
4 |
0 |
6 |
0 |
да |
||
TAC Xenta 301 |
TP/FT-10 |
4 |
4 |
4 |
6 |
2 |
да |
2 модуля |
|
TAC Xenta 302 |
TP/FT-10 |
4 |
4 |
4 |
4 |
4 |
да |
2 модуля |
|
TAC Xenta 401 |
TP/FT-10 |
0 |
0 |
0 |
0 |
0 |
да |
10 модулей |
|
Модули расширения |
|||||||||
Модель |
Сеть |
Dl |
Tl |
Ul |
DO |
AO |
Сертификат LonMark |
Дополнительно |
|
TAC Xenta 411 |
TP/FT-10 |
10 |
0 |
0 |
0 |
0 |
|||
TAC Xenta 412 |
TP/FT-10 |
10 |
0 |
0 |
0 |
0 |
Индикаторы состояния |
||
TAC Xenta 421A |
TP/FT-10 |
0 |
0 |
4 |
5 |
0 |
да |
||
TAC Xenta 422A |
TP/FT-10 |
0 |
0 |
4 |
5 |
0 |
да |
Ручные переключатели состояний выходов и индикаторы состояния |
|
TAC Xenta 451A |
TP/FT-10 |
0 |
0 |
8 |
0 |
2 |
да |
||
TAC Xenta 452A |
TP/FT-10 |
0 |
0 |
8 |
0 |
2 |
да |
Ручные переключатели состояний выходов и индикаторы состояния |
|
TAC Xenta 471 |
TP/FT-10 |
0 |
0 |
8 |
0 |
0 |
0-10 V DC, 0-20 мA |
||
TAC Xenta 491 |
TP/FT-10 |
0 |
0 |
0 |
0 |
8 |
|||
TAC Xenta 492 |
TP/FT-10 |
0 |
0 |
0 |
0 |
8 |
Ручные переключатели состояний выходов |
||
Специализированные контроллеры |
|||||||||
Модель |
Сеть |
Dl |
Al |
Ul |
DO |
AO |
Сертификат LonMark |
Применение |
Дополнительно |
TAC Xenta 121-FC/24 |
TP/FT-10 |
3 |
3 |
1 |
8 |
1 |
eu.bac cert |
Фанкойл |
|
TAC Xenta 121-FC/230 |
TP/FT-10 |
3 |
3 |
1 |
8 |
1 |
eu.bac cert |
Фанкойл |
Встроенный трансформатор |
TAC Xenta 121-HP/24 |
TP/FT-10 |
3 |
3 |
1 |
8 |
1 |
да |
Тепловой насос |
|
TAC Xenta 121-HP/230 |
TP/FT-10 |
3 |
3 |
1 |
8 |
1 |
да |
Тепловой насос |
Встроенный трансформатор |
Комнатные датчики |
|||||||||
Модель |
Сеть |
Дополнительно |
|||||||
STR 350 |
TP/FT-10 |
Многофункц, настраиваем. настен. датчик с ЖК дисплеем, датч. темп. и т.д. |
|||||||
STR 351 |
TP/FT-10 |
Многофункц, настраиваем. настен. датчик с ЖК дисплеем, датч. темп. и т.д. |
Дисплей с подсветкой |
||||||
Сетевые решения |
|||||||||
Модель |
Сеть |
||||||||
TAC Xenta 511 |
TP/FT-10 |
Web-сервер для сети LonWorks, контроль и управление вашей системой через Internet или локальную сеть |
|||||||
TAC Xenta 901 |
TP/FT-10 |
Последовательный адаптер Lon® Talk для дозвона до TAC VistaTM по стандартной телефонной линии |
|||||||
TAC Xenta 911 |
TP/FT-10 |
МодеМ LonWorks® в TCP/IP, обеспечивает функциональность работы по дозвону в сети TCP/IP |
|||||||
TAC Xenta 913 |
TP/FT-10 |
Шлюз с поддержкой множества протоколов, LonWorks® в/из Modbus, M-bus или BACnetTM |
|||||||
TAC Xenta Repeater |
TP/FT-10 |
Повторитель сигнала для сети TP/FT-10 |
|||||||
TAC Xenta OP |
TP/FT-10 |
Панель оператора для устройств LonWorks® , портативная либо установленная |
AO = Аналоговый выход DI = Цифровой вход DO = Цифровой выход TI = Термисторный вход
UI = Универсальный вход
Панель оператора модификации TAC Xenta ОР производства французского концерна Schneider Electric предназначается для возможности осуществления управления показателями. Кроме того, подобное приспособление используется для получения информационных сведений о сигналах непосредственно при применении с любыми моделями свободно программируемых контроллеров линейки TAC Xenta Шнайдер Электрик.
Принципы работы, предназначение и сфера использования операторских панелей модификации TAC Xenta ОР
TAC Xenta OP представляет собой кнопочную панель небольших габаритных размеров. Используя данное приспособление, оператор может осуществлять управление такими моделями программируемых логических контроллеров из коллекции TAC Xenta, как ПЛК 100, 280, 300, 401 и 901. Управленческая панель данного вида оборудована жидкокристаллическим монитором, который состоит из четырех строк по двадцать символов в каждой. Также на операторской панели имеется шесть кнопок для выполнения управления контроллерами.
При необходимости устройство можно с легкостью зафиксировать на самом программируемом контроллере, например, на передней внешней дверце щитка. Как вариант, панелью оператор может пользоваться как переносным приспособлением и осуществлять управление на определенной дистанции.
При помощи эксплуатации такого прибора можно с удобством осуществлять регулирование контроллеров линейки TAC Xenta. Вводить необходимые данные можно, используя шесть функциональных клавиш, при этом информация будет выводиться на жидкокристаллический экран с подсветкой. Это весьма удобно. Поэтому всем, у кого есть потребность эффективно управлять программируемыми ПЛК в системах промышленной автоматизации, рекомендуется операторскую панель Tac Xenta купить и применять на практике. Подобный инструмент существенно упростит работу с системой.
Где можно приобрести операторские панели Tac Xenta op по выгодной цене?
Фирменную продукцию компании Schneider Electric, в частности операторские панели Tac Xenta op, купить любой потребитель может, сделав заказ на сайте фирмы fgrus.ru, которая многие годы является одним из лучших импортеров высококачественных продуктов зарубежных и отечественных брендов. Компания гарантирует доставку товаров в целости и сохранности в самые кратчайшие сроки в любой населенный пункт РФ, включая страны СНГ.
К тому же, в интернет-магазине fgrus.ru предлагаются справедливые цены на все панели операторов Шнайдер Электрик и другие позиции из электронного каталога.
TAC Vista
TAC Pangaea
WorkStation
TAC Xenta OP
Operating Manual
TAC Vista
TAC Xenta OP
Operating Manual
Copyright © 2007-2010 Schneider Electric Buildings AB. All rights reserved.
This document, as well as the product it refers to, is only intended for licensed users. Schneider Electric Buildings AB owns the copyright of this document and reserves the right to make changes, additions or deletions. Schneider Electric Buildings AB assumes no responsibility for possible mistakes or errors that might appear in this document.
Do not use the product for other purposes than those indicated in this document.
Only licensed users of the product and the document are permitted to use the document or any information therein. Distribution, disclosure, copying, storing or use of the product, the information or the illustrations in the document on the part of non-licensed users, in electronic or mechanical form, as a recording or by other means, including photo copying or information storage and retrieval systems, without the express written permission of Schneider Electric Buildings AB, will be regarded as a violation of copyright laws and is strictly prohibited.
Trademarks and registered trademarks are the property of their respective owners.
TAC Xenta, TAC Xenta OP |
Contents |
Contents
INTRODUCTION
1 About this Manual |
9 |
|
1.1 |
Structure ……………………………………………………………………………………………………… |
9 |
1.2 |
Typographic Conventions ……………………………………………………………………………… |
9 |
REFERENCE
2 Introduction |
13 |
|
2.1 |
TAC Xenta OP …………………………………………………………………………………………….. |
13 |
2.2 |
This Manual ………………………………………………………………………………………………… |
13 |
2.3 |
More information …………………………………………………………………………………………. |
14 |
3 Connection and Basic Functions |
15 |
|
3.1 |
Description ………………………………………………………………………………………………….. |
15 |
3.2 |
Connecting to TAC Xenta 100……………………………………………………………………….. |
16 |
3.3 |
Connecting to TAC Xenta 280/300/401 ………………………………………………………….. |
16 |
3.4 |
Keys……………………………………………………………………………………………………………. |
18 |
3.5 |
Local Functions of the OP Service Menu ………………………………………………………… |
19 |
3.5.1 |
Two Hardware Tests …………………………………………………………………………………….. |
19 |
3.5.2 |
System Information………………………………………………………………………………………. |
20 |
3.5.3 |
Selecting the Language of the OP Messages ……………………………………………………. |
20 |
3.5.4 |
Controlling the Display Light ………………………………………………………………………… |
20 |
3.5.5 |
Leaving the OP Service Menu ……………………………………………………………………….. |
21 |
3.5.6 |
Selecting the OP Mode………………………………………………………………………………….. |
21 |
3.6 |
Selecting the OP Communication Mode………………………………………………………….. |
21 |
3.6.1 |
Summary …………………………………………………………………………………………………….. |
22 |
3.6.2 |
Bindable ……………………………………………………………………………………………………… |
23 |
3.7 |
Remove the OP ……………………………………………………………………………………………. |
24 |
3.7.1 |
Tool: MetraVision………………………………………………………………………………………… |
24 |
3.7.2 |
Tool: LonMaker …………………………………………………………………………………………… |
25 |
4 Dialogs with TAC Xenta 100 |
27 |
|
4.1 |
General ……………………………………………………………………………………………………….. |
27 |
4.2 |
Connecting to TAC Xenta 100……………………………………………………………………….. |
27 |
4.3 |
Setting the Node State in TAC Xenta 100 ……………………………………………………….. |
28 |
4.4 |
Reading/Checking NVs in TAC Xenta 100 ……………………………………………………… |
29 |
4.5 |
Initiate Service Pin Message ………………………………………………………………………….. |
30 |
5 Dialogs with TAC Xenta 280/300/401 |
31 |
|
5.1 |
The Menus…………………………………………………………………………………………………… |
31 |
5.2 |
Find and Change a Setpoint …………………………………………………………………………… |
32 |
Schneider Electric Buildings AB, Mar 2010 |
5 (46) |
04-00065-01-en |
Contents |
TAC Xenta, TAC Xenta OP |
|
5.3 |
View/Acknowledge Alarms |
…………………………………………………………………………… 33 |
5.4 |
Change the Time Channels…………………………………………………………………………….. |
35 |
5.5 |
Access Code ………………………………………………………………………………………………… |
37 |
5.6 |
Edit Access Code………………………………………………………………………………………….. |
37 |
5.7 |
Overriding Inputs/Outputs……………………………………………………………………………… |
38 |
5.8 |
Daylight Saving ……………………………………………………………………………………………. |
38 |
5.9 |
Log Off ……………………………………………………………………………………………………….. |
39 |
6 Technical Data |
41 |
|
Index |
43 |
6 (46) |
Schneider Electric Buildings AB, Mar 2010 |
04-00065-01-en |
INTRODUCTION
1 About this Manual
TAC Xenta, TAC Xenta OP |
1 About this Manual |
1 About this Manual
This manual describes a particular process. For information on certain products, we refer you to the manual or the Help for the product in question.
For information on how to install software, we refer you to the instructions delivered with the software.
For information on third party products, we refer you to the instructions delivered with the third party product.
If you discover errors and/or unclear descriptions in this manual, please contact your Schneider Electric representative.
Note
•We are continuously improving and correcting our documentation. This manual may have been updated.
Please check our Docnet site at
for the latest version.
1.1Structure
The manual is divided into the following parts:
•Introduction
The Introduction section contains information on how this manual is structured and how it should be used to find information in the most efficient way.
•Reference
The Reference section contains more comprehensive information about various parts of the Getting Started section. It also provides you with information on alternative solutions not covered by the Getting Started section.
1.2Typographic Conventions
Throughout the manual the following specially marked texts may occur.
Schneider Electric Buildings AB, Mar 2010 |
9 (46) |
04-00065-01-en |
1 About this Manual |
TAC Xenta, TAC Xenta OP |
!Warning
•Alerts you that failure to take, or avoid, a specific action might result in physical harm to you or to the hardware.
Caution
•Alerts you to possible data loss, breaches of security, or other more serious problems.
Important
•Alerts you to supplementary information that is essential to the completion of a task.
Note
•Alerts you to supplementary information.
Tip
•Alerts you to supplementary information that is not essential to the completion of the task at hand.
Advanced
•Alerts you that the following information applies to complex tasks or tasks restricted by access.
10 (46) |
Schneider Electric Buildings AB, Mar 2010 |
04-00065-01-en |
REFERENCE
2Introduction
3Connection and Basic Functions
4Dialogs with TAC Xenta 100
5Dialogs with TAC Xenta 280/300/ 401
6Technical Data
TAC Xenta, TAC Xenta OP |
2 Introduction |
2 Introduction
2.1TAC Xenta OP
TAC Xenta OP is a small operator panel designed to be used together with TAC Xenta 100, 280, 300, 401 and 901 units.
The operator panel gives the user access to parameters and alarms without communicating with a central system. Additionally, it is used to monitor status, adjust setpoints and time channels. All values are displayed with an explanatory text in the alphanumeric display window.
Caution
•The TAC Xenta OP and the other products of the Xenta family must not be used for any other purpose than that for which it was designed.
•Installation and repair may only be performed by authorized personnel.
2.2This Manual
This handbook has the following contents:
Chapter 2
In this chapter the connection of the operator panel, TAC Xenta OP, to the TAC Xenta 100/280/300/401 controllers is shown.
Chapter 3
The use of the OP together with TAC Xenta 100 and the principles for handling display of Network Variables are explained in this chapter.
Chapter 4
The use of the OP together with TAC Xenta 300/401 controllers and the most common menus are discussed here.
Chapter 5
This chapter contains technical data on the TAC Xenta OP.
Schneider Electric Buildings AB, Mar 2010 |
13 (46) |
04-00065-01-en |
2 Introduction |
TAC Xenta, TAC Xenta OP |
2.3More information
TAC Xenta OP is also described or mentioned in the following documents:
•The TAC Xenta OP Operator panel data sheet
•The handbooks for the different TAC Xenta controller units
•The TAC Menta User’s manual
Stand-alone TAC Xenta 300/3000 controllers and I/O modules can be commissioned by using the Service menu of TAC Xenta OP (which is not the same as the local OP service menu). This procedure is described in the TAC Xenta 300 and 401 Handbook.
14 (46) |
Schneider Electric Buildings AB, Mar 2010 |
04-00065-01-en |
Loading…
You can only view or download manuals with
Sign Up and get 5 for free
Upload your files to the site. You get 1 for each file you add
Get 1 for every time someone downloads your manual
Buy as many as you need
Уважаемые специалисты, я прошу совета. Во вверенном мне на работе хозяйстве есть ИТП. Делает из холодной воды горячую, и в принципе, со своей работой как-то справляется, но. Я ни как не могу это контролировать.
Там есть насосы, датчики, запорная арматура с электроприводами и всë это подключено к шкафу управления собранному на контроллерах Xenta. Насосы качают, приводы двигаются, лампочки на двери шкафа загораются и на выходе с ИТП имеем воду примерно 56 градусов. Но на этот шкаф нет ни какой документации. Он не подключен ни к какой диспетчеризации. У него нет практически ни каких органов управления. И если это всë однажды встанет или, скажем, нужно будет что-то изменить в работе (например температуру), то это будет катастрофа. Кроме того иногда загорается красная лампа «Авария», а я даже не знаю в чëм она заключается, ведь вроде всë работает, как обычно.
Я предполагаю, что мне здесь сейчас скажут, что мол надо вызвать специалистов, однако. И я с вами полностью согласен! Этим я и занимался последние несколько месяцев. Но заглянув внутрь шкафа, эти «специалисты» становятся не такими самоуверенными, как до этого. Начинают, что-то лепетать типа «Ну тут это, того, исходники все нужны и документация». После чего обещают подумать над нашей проблемой и исчезают навсегда.
Дело в том, что город у нас провинциальный, и не такой технически развитый как, скажем Москва, Питер, Казань или Самара. Собирали это всë специалисты из другого города. Но из-за каких-то разногласий (скорее всего из-за бабла) связь с ними прервана навсегда. Я сам человек в общем-то не глупый, «Радиоинженер-конструктор-технолог» — написано в моëм дипломе. Но никогда раньше не имел дела с контроллерами Xenta. Но может есть хоть какой-нибудь шанс у меня с этим разобраться. Почитать, посоветоваться и т.д. Или всë действительно безнадëжно? Если шанс есть, то подскажите пожалуйста с чего начать?
Да, забыл сказать, контроллер: TAC Xenta 721 и переферия: TAC Xenta 411, TAC Xenta 421A, TAC Xenta 451A.
«Радиоинженер-конструктор-технолог» — написано в молм дипломе.
TAC Xenta 721 и переферия
Диплом есть, значит — «высшее образование», «специалист».
. Но неграмотный.
У нас в одной котельной сначала тоже был щит с TAC Xenta:
. А потом стал немного другим:
Попробуйте пока подключиться к 721-му по ethernet, может вас на веб-сервер пустят. пароли типа admin-admin иногда проскакивают по оплошности программера. Так-то там и программу должно быть видно на FBD языке. Скачайте инструкцию к контроллеру 721
http://yandex.ru/clck/jsredir?from=yandex. 487285058393979
Так-то можно найти и скаду ихнюю, но там всё сложно настраивается, без спеца в оффлайне наврядли получится. Какой город-то?
Инструкцию читал. Она больше похожа на рекламу, чем на даташит. Читал и ещë несколько мануалов на русском и английском. Но так и не понял как войти с компьютера через Ethernet. Я пробовал так: подключил контроллер проводом к роутеру. Думаю сейчас DHCP выдаст ему IP — адрес, я его посмотрю через интерфейс роутера, вобью в браузере и попаду в какую-нибудь вебморду. И тут возможно я зависну над паролем. А если подберу, то хоть гляну, «что там внутри», а дальше по обстоятельствам. Но случилось, то чего я не ожидал: роутер его проигнорировал, т.е. как бы я ни чего и не подключил, но лампочка на роутере загорелась. Перезагружал и то, и другое в разных комбинациях — не помогло. И я подумал, что с контроллерами этот номер не прокатывает. Решил спросить. А вот сейчас думаю, может провод попался хреновый.
Программу контроллера я менять не собираюсь, все работает вроде. Хотелось бы узнать, что там за ошибки (сейчас «Авария» горит постоянно, но при этом всë работает), может датчик какой менять надо пока не поздно. И хорошо бы иметь возможность поменять параметры. Ну там температуру, например, или время работы насосов.
Здесь 2 варианта: 1. Где-то стоит пульт управления, о котором вы не знаете и с которого и настраиваются контроллеры. 2. Контроллеры просто подключаются к ноутбуку и программируются напрямую.
Спросите у Google, как их настроить. Например, тут https://www.schneider-electric.us/en/downlo. ent/03-00045-06.
Для не специалиста тяжело.
Кроме IP адреса и пароля нужен софт — XBuilder и Мента. Программа (программы) лежат внутри контроллера 721. IP адрес мохно посмотреть через Терминал с использованием спец кабеля. Но без знания пароля никак. По умолчанию root/root. IP 192.168.255.2.
Для просмотра и управления в процессе эксплуатации нужна панель оператора ОР7 или ТАС Виста.
Есть другой вариант. Заменить 721 на Xenta 401, использовать панель ОР. Заказать (написать самому) программу для 401.
Стоит денег, но зато владение ситуации в полном объеме.
Вот такая панель оператора должна быть ссылка
С ней подключаетесь к контроллеру и там должно отображаться меню, авария и тд.
Панель оператора — это хорошо, но еë сначала надо купить, а также купить Xenta 401 и установить его вместо 721. Затем за деньги всë это запрограммировать, и тогда настанет счастье. Но боюсь я не смогу объяснить руководству, почему они должны выделить под этот проект, как я понял, сотни тысяч рублей, если горячая вода у нас и так есть.
Всем, кто откликнулся — большое спасибо. Обязательно попробую вариант с кабелем RS232. К сожалению сейчас приболел, вот выйду с больничного, тогда. По результатам, отпишусь.
Вот такая панель оператора должна быть ссылка
С ней подключаетесь к контроллеру и там должно отображаться меню, авария и тд.
Как прозвонить контроллер xenta tac 421
Контроллер TAC Xenta 421A относится к семейству программируемых контроллеров с возможностями коммуникаций, разработанных для систем отопления и кондиционирования воздуха.
Контроллер TAC Xenta поддерживает выполнение полного набора функций, включая построение графиков, обработку аварийных сигналов и т. д.
Контроллер не имеет собственных входов и выходов. Вместо них используются модули входов/выходов серии TAC Xenta 421A.
К контроллеру TAC Xenta может быть подключено до 10 модулей входов/выходов. Этот контроллер предназначен для установки в шкафу.
Контроллер TAC Xenta программируется и вводится в эксплуатацию с использованием графического инструмента программирования TAC Menta.
Контроллер подключается к сети LonTalk TP/FT-10 по неполяризованному кабелю (по витой паре). Контроллер может функционировать как автономный блок, так и в составе системы.
Контроллер TAC Xenta 421A может быть подключен к модему или к системе диспетчеризации TAC Vista.
Контроллер может быть отключен/подключен к контактной части без отключения питания. При добавлении или замене контроллера может быть выполнено предварительное конфигурирование для использования функциональных возможностей Plug and Play (Включай и работай) для предотвращения конфигурирования на месте установки оборудования.
Для локального использования может быть подключена панель оператора TAC Xenta. Панель оператора содержит дисплей и клавиатуру для навигации по системе меню и изменения установок. Панель оператора может быть подключена к контроллеру TAC Xenta, смонтированному в передней части шкафа, либо используется как переносной терминал.
TAC Xenta 421A Manuals
Download TAC Xenta 421A I/O Systems PDF User Guides and Manuals: Found (2) Manuals for TAC Xenta 421A Device Model (Configuration Instruction, Manual )
- Product ID: #1656054
- Category: I/O Systems
- File Path: tac/xenta-421a_1656054.pdf
- Pages: 48
- Product ID: #1656055
- Category: I/O Systems
- File Path: tac/xenta-421a_1656055.pdf
- Pages: 4
Related for TAC Xenta 421A Manuals, Service Instructions:
Device: PCI-DAS6013, 29 Sep 2022 (#B89PTA)
Device: 75314113, 24 May 2023 (#G11O53)
Device: OPT-MF-001, 03 Oct 2022 (#2Y146I)
Device: PCI-DIO48H, 11 Jul 2023 (#HH5JS4)
Device: Xenta 411, 02 Feb 2023 (#Z63QD7)
Device: NI USB-6008, 24 Sep 2022 (#QP9P27)
1I2 I1 4 13 2LEDLASW676002211IISTRUZIONI PERL’INSTALLAZIONEOH/IR è equipaggiato con un ricevitore IR per telecomandi e 2 ingressi digitali.Il modulo deve essere utilizzato in siste-mi domotici CAME.Il ricevitore viene pilotato dal teleco-mando OH/IRTX1, da telecomandi con codifica NEC o universali in grado di appre .
roboRIO
USER MANUALNI roboRIORIO Device for RoboticsThe NI roboRIO is a portable reconfigurable I/O (RIO) device that is used to design control,robotics, and mechatronics systems.This document contains pinouts, connectivity information, dimensions, and mountinginstructions for the NI roboRIO. The NI roboRIO provides the I/O sh .
Simatic ET 200S
Technological Functions _______________________________________________________________________________________________ SIMATIC ET 200S Technological Functions Operating Instructions 06/2010 A5E00124867-07 Preface 1 1Count24V 2 1Count5V 3 1SSI 4 2PULSE 5 .
AF-650 GP
AF-650 GPTM General Purpose Drive High Power (460/575/690V 125HP and above)Operating InstructionsThe instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information b .
Как прозвонить контроллер xenta tac 421
Контроллер TAC Xenta 421A относится к семейству программируемых контроллеров с возможностями коммуникаций, разработанных для систем отопления и кондиционирования воздуха.
Контроллер TAC Xenta поддерживает выполнение полного набора функций, включая построение графиков, обработку аварийных сигналов и т. д.
Контроллер не имеет собственных входов и выходов. Вместо них используются модули входов/выходов серии TAC Xenta 421A.
К контроллеру TAC Xenta может быть подключено до 10 модулей входов/выходов. Этот контроллер предназначен для установки в шкафу.
Контроллер TAC Xenta программируется и вводится в эксплуатацию с использованием графического инструмента программирования TAC Menta.
Контроллер подключается к сети LonTalk TP/FT-10 по неполяризованному кабелю (по витой паре). Контроллер может функционировать как автономный блок, так и в составе системы.
Контроллер TAC Xenta 421A может быть подключен к модему или к системе диспетчеризации TAC Vista.
Контроллер может быть отключен/подключен к контактной части без отключения питания. При добавлении или замене контроллера может быть выполнено предварительное конфигурирование для использования функциональных возможностей Plug and Play (Включай и работай) для предотвращения конфигурирования на месте установки оборудования.
Для локального использования может быть подключена панель оператора TAC Xenta. Панель оператора содержит дисплей и клавиатуру для навигации по системе меню и изменения установок. Панель оператора может быть подключена к контроллеру TAC Xenta, смонтированному в передней части шкафа, либо используется как переносной терминал.
Как прозвонить контроллер xenta tac 421
Программируемый контроллер TAC Xenta 280
TAC Xenta 280 принадлежит к группе программируемых контроллеров, предназначенных для зонального управления, а также для управления небольшими системами отопления и вентиляции.
TAC Xenta 280 обладает полным набором функций необходимых для управления системами отопления, вентиляции и кондиционирования, включая расчет контуров управления, построение графиков, обработку аварийных сообщений и т.д.
Контроллеры серии TAC Xenta 280 выпускаются в трех модификациях — TAC Xenta 281, 282 и 283, которые различаются конфигурацией входов/выходов.
TAC Xenta 280 легко программируется и запускается с помощью графического инструмента программирования TAC Menta. Контроллер монтируется щите автоматики.
К другим устройствам сети LONTALK TP/FT-10 контроллер подключается при помощи кабеля витая пара. TAC Xenta 280 может функционировать как сам по себе, так и как часть большой системы, основанной на сети LonWorks. Для локального управления к контроллеру подключается панель оператора TAC Xenta OP.
Подробнее
Техническое описание TAC Xenta 280
Программируемый контроллер TAC Xenta 401
TAC Xenta 401 принадлежит к группе программируемых контроллеров c возможностью установки соединения, разработанных для систем отопления и кондиционирования. TAC Xenta 401 обладает всеми полным набором функций необходимых для управления системами отопления, вентиляции и кондиционирования, включая расчет контуров управления, построение графиков, обработку аварийных сообщений и т.д.
Контроллер не имеет собственных входов и выходов. Необходимые входы и выходы компонуются модулями входов/выходов серии ТАС Xenta 400 . К TAC Xentа 401 подключается до 10-ти дополнительных модулей.
ТАС Xenta 401 легко программируется и запускается при помощи графического инструмента программирования TAC Menta. Контроллер монтируется на щите автоматики.
Контроллер TAC Xenta 401 может функционировать как сам по себе, так и как часть большой системы. К другим устройствам сети LONTALK TP/FT-10 контроллер подключается при помощи кабеля витая пара.
TAC Xenta 401 может устанавливать соединение с модемом или с центральной системой TAC Vista. Для локального управления к контроллеру подключается панель оператора TAС Xenta OP.
Программируемый контроллер TAC Xenta 300
TAC Xenta 300 принадлежит к группе свободно программируемых контроллеров, предназначенных для управления системами отопления и кондиционирования небольшого размера. Контроллер обладает полным набором функций управления системами отопления, вентиляции и кондиционирования, включая расчет контуров управления, построение графиков, обработку аварийных сообщений и т.п.
Контроллеры TAC Xenta® 300 выпускаются в двух версиях: TAC Xenta 301 и TAC Xenta 302, которые различаются конфигурацией входов/выходов. Обе модели имеют 12 входов (4 цифровых входа, 4 аналоговых входа и 4 входа для датчиков) и 8 выходов (6 цифровых и 2 аналоговых у TAC Xenta 301 и 4 цифровых и 4 аналоговых у TAC Xenta 302) При необходимости контроллер компонуется дополнительными модулями входов/выходов. Контроллер и блоки расширения монтируются на щите управления.
ТАС Xenta 300 легко программируется и запускается при помощи графического инструмента программирования TAC Menta.
Контроллер TAC Xenta 300 может функционировать как сам по себе, так и как часть большой системы. К другим устройствам сети LONTALK® TP/FT-10 контроллер подключается при помощи кабеля витая пара.
TAC Xenta 300 устанавливает соединение с модемом или с центральной системой TAC Vista. Для локального управления к контроллеру подключается панель оператора TAС Xenta OP.
Модули цифровых входов TAC Xenta 411/412
Используются как блоки расширения для контроллеров TAC Xenta и подключаются к основному контроллеру через общую сеть.
Оба модуля имеют по десять цифровых входов, которые можно использовать как счетчики импульсов. Входы TAC Xenta 412 имеют дополнительные индикаторы состояний (светодиоды). Красный или зеленый цвет индикаторов определяется переключателями на передней панели
Модули TAC Xenta411/412 подключаются к базовому контроллеру при помощи графического инструмента программирования TAC Menta. Если в одной сети несколько контроллеров и блоков расширения, для ее отладки нужно использовать программу конфигурации Device Configuration Tool РС.
Состояние цифровых входов можно проверить через дисплей панели оператора TAС Xenta OP, подключенной к любому контроллеру той же сети.
Модули аналоговых входов/выходов TAC Xenta 451/452
Используются в качестве блоков расширения и подключаются к контроллерам TAC Xenta через общую сеть.
Оба модуля имеют 4 универсальных входа, 4 термисторных входа и по два аналоговых выхода. Универсальные входы могут использоваться для получения импульсных сигналов, а также в качестве цифровых входов.
Модуль TAC Xenta 452 имеет индикаторы состояний (светодиоды) для каждого универсального входа и переключатели для ручной блокировки выходов. Красный или зеленый цвет светодиодов определяется переключателями на передней панелью.
Модули TAC Xenta 451/452 подключаются к контроллеру при помощи графического инструмента программирования TAC Menta. Если сеть включает несколько контроллеров с блоками расширения, то для подключения используется программа настройки Device Configuration Tool PC.
Состояние входов/выходов можно проверить через дисплей панели оператора TAС Xenta OP, подключенной к любому контроллеру в сети.
Модули цифровых входов/выходов TAC Xenta 421/422
Используются в качестве блоков расширения и подключаются к контроллерам TAC Xenta через общую сеть.
Оба модуля имеют 4 цифровых входа и 5 выходов. Входы могут использоваться также для получения импульсных сигналов. Модуль TAC Xenta 422 имеет дополнительно индикаторы состояний (светодиоды), по одному для каждого цифрового входа, и переключатели для выходов. Цвет индикаторов, красный или зеленый, выбирается при помощи переключателя на передней панели
Модули TAC Xenta 421/422 подключаются к контроллеру при помощи графического инструмента программирования TAC Menta. Если сеть включает несколько контроллеров с блоками расширения, то для подключения используется программа Device Configuration Tool PC.
Состояние входов/выходов можно проверить через дисплей панели оператора TAС Xenta OP, подключенной к любому контроллеру в сети.
TAC Xenta
The red service diode is primarily an error indication. It also lights up if the Service pin is activated.
- A solid red light usually indicates that the hardware has failed. Please see a few simple steps to deactivate the solid red light below.
- Use a reset dongle to wipe the controller then reinstall the firmware and menta program.
- If the controller is the group master you might try to assign a different controller to group master. This method has not been proven but has worked before during internal testing.
NOTE: The hardware may need to be replaced if the solid red light continues after these steps.
- If the red indicator light is blinking once per second this will indicate a non-configured node.
- If the controller has been commissioned you might try to decommission the controller and try again.
- If the red indicator light is off this would indicate that it has been commissioned and added properly to the network. You should not see the red indicator light if the controller is working properly.
- The green status diode blinks once per second to indicate that the program is running properly. (В нормальном режиме при штатном выполнении программы, светодиод мигает с чвстотой 1Гц. Если поисходит программное зависание контроллера- светодиод светится зеленым цветом.
- Но! часто из-за условий эксплуатации оборудования в режиме повышенной температуры окружающей среды помимо рассыхания пластмассовых деталей, «высыхания» электролитических конденсаторов, возникают проблемы с пайкой — нарушается контакт, а также «теряют» сопротивление резисторы. Так, в частности несколько раз встречалась проблема, связанная с отсутствием индикации при полной работоспособности контроллера — терял сопротивление резистор в цепи «светодиод-коллектор управляющего транзистора». )
- По аналогичной причине (повышенная температура окружающей среды) возникают сходные проблемы с операторской панелью что може привести в частности к такому дефекту как «квадратики» вместо символов
- .AUT Text file with application program source code and data including graphical block diagram.
- .TLG The trendlog definition.
- .MCB Macro block file (Group of blocks).
- .COD “Machine code” file in ASCII format for downloading to the TAC Xenta controller.
- .XLG The compiled trendlog definition.
- .ESP Specification file with public signals, their attributes etc. generated by TAC Menta. This file contains input data to the OP configuration tool.
- .OPE A file with an empty tree, i.e. an OP tree without a specification file. This is the kind of file that is created when the OP configuration tool is run from the program manager.
- .OPC A mix of an .OPE and an .ESP file. This file is created by the OP configuration tool when it has been invoked from TAC Menta.
- .BIN Binary file with OP menu tree data for downloading to the TAC Xenta controller together with the .COD file.
- .CHR National character set file for downloading to the TAC Xenta controller together with the
.COD file. - .XIF External interface file containing a standardized description of all network variables/ objects of the application program. The .XIF enables binding and communication with LonWorks nodes from other manufacturers.
- .MTA Menta project file, which can include all files (all types mentioned above except for .MCB and .OPE) related to a certain application. Once a file (for example .AUT or .OPC) has been inserted (saved) in the project file, it can be extracted (opened) anytime as an .MTA file. The .MTA file can be stored directly in the TAC Vista database.
Note:
The .MTA file can be stored in the TAC Vista database even though it can not be compiled. An .MTA file which is not compilable will not, of course, be possible to download into a TAC Xenta device. It must be correct and compilable before download is possible. In addition to the files listed above, the following data files are involved in the creation of the .BIN file. These files are placed in a specific directory for temporary files. - OPDOC.GOP An ASCII file created by the OP configuration tool when the Generate command is executed. This file is converted to an .SPT file, which in turn is converted to a .BIN file
- OPDOC.SPT Intermediate ASCII file generated from the.GOP file.
- OPDOC.TMP Intermediate ASCII file generated from the.GOP file.
- BPR The Network Neighborhood file, describing the TAC Xenta device’s surrounding network nodes and groups.
Возможные неисправности:
— при включении блока (например 421), светится зеленый светодиод, по сети не виден. Необходимо проверить конденсаторы в цепях питания (ESR).
Для отображения русского языка на панели Xenta OP необходимо в редакторе TAC Menta -> OP configuration -> Formats -> Settings убрать:
— use system menu
— OP: custom
Ремонт TAC CONTROLLER XENTA 401 — 0-073-0101-2
Ремонт TAC CONTROLLER XENTA 401; 0-073-0101-2. Последовательная диагностика и ремонт на компонентном уровне производится в Санкт-Петербурге. Возможно выполнение ремонтных работ с доставкой оборудования в населенные пункты России.
Электроника оборудования состоит из следующих блоков: схема измерения характеристик (разработана на основе: датчика тока, источника опорного напряжения, защитных диодов, делителя напряжения, датчика температуры, операционного усилителя, активного фильтра, аналого-цифрового преобразователя) — предназначена для преобразования в электрический сигнал смещений контролируемых параметров; индикаторная схема (содержит: ЖК дисплей, декодер, светодиоды, драйвер, токоограничительные резисторы) — формирует преобразованную информацию о последнем состоянии устройства и присоединенных датчиков; схема автоматической самодиагностики (выполнена на основе: модуля внутрисхемного тестирования, модуля проверки контрольной суммы, модуля опроса датчиков, сторожевого таймера, интерфейса отладки) — позволяет оценить состояние устройства при запуске; плата контроллера питания (состоит из: трансформатора, выпрямительных диодов, стабилизатора, сглаживающего фильтра) — гарантирует снабжение всех составляющих частей устройства стабильным напряжением постоянного тока; схема управления (состоит из: цифрового процессора, постоянного запоминающего устройства, цифро-аналогового преобразователя, шины данных, интерфейса связи, гальванической развязки, кварцевого генератора, модуля цифровых входов, оперативной памяти, устройства программирования, модуля выходов) — это узел для реализации алгоритма функционирования микроэлектронного устройства в целом и обеспечивает предусмотренное выполнение нужных функций в соответствии с назначением.
Условия ремонта
Примеры серийных номеров на шильде
Для получения самой актуальной информации о конкретной стоимости и сроке выполнения данных услуг пришлите заявку с описанием внешних проявлений неисправностей на адрес электронной почты [email protected]
Панель оператора TAC Xenta OP — обеспечивает удобное локальное управление контроллерами TAC Xenta. Ввод данных осуществляется при помощи 6 клавиш, а информация отображается на ЖК-дисплее с подсветкой. Подсветку дисплея, при необходимости, можно выключить, изменив соответствующий параметр. Панель оператора подключается к контроллеру при помощи модульного разъёма, который обеспечивает подачу питания от контроллера и возможность связи. Панель можно подключить непосредственно в сеть LonWorks. Пользователь получает доступ ко всем контроллерам из любой точки сети. Панель оператора позволяет контролировать текущее состояние и менять уставки, временные расписания и т.п. без подключения к центральной системе. Кроме того, для удобства пользования конструкция панели предусматривает возможность её установки непосредственно на контроллер TAC Xenta, на дверцу шкафа управления или возможность пользоваться ей как переносной. Современное и функциональное исполнение. Совместима с TAC Xenta 100, TAC Xenta 280, TAC Xenta 300 и TAC Xenta 401.
Функциональные особенности TAC Xenta OP:
- Простая в использовании панель оператора
- дисплей с подсветкой на 4 X 0 цифро-буквенных символов
- Поддержка контроллеров серий TAC Xenta 100, 280, 300 и 400
- Позволяет загружать наборы символов, например, кириллицу.
- Связь по сети LonWorks
- одна панель OP обеспечивает связь со всеми устройствами Xenta
- Панель оператора может быть закреплена на контроллере Xenta или смонтирована на дверце шкафа
Технические данные TAC Xenta OP:
напряжение питания . . . . . . . . . . . . . . 4 V AC/DC ± 0% от TAC Xenta
или внешнее
Потребление энергии . . . . . . . . . . . . .макс. 0.5 вт
размеры . . . . . . . . . . . . . . . . . . . . . . . . . . .114 x 96 x 4 мм
Протокол связи . . . . . . . . . . . . . . . . . . . .FTT-10, LonTalk
Скорость передачи данных . . . . . . .78 кбит/сек
допустимая температура
При хранении . . . . . . . . . . . . . . . . . . . . .от – 0 °C до +50 °C